Carbolite Gero – Laboratory Chamber Furnace
Carbolite Gero’s extensive chamber furnace range has a maximum operating temperature of 1800°C and chamber capacities up to 725 liters. They are suitable for a variety of laboratory, pilot scale and industrial applications. Although there is flexibility in size and temperature, if the application requires the use of modified atmosphere (above 1100°C) or vacuum then a furnace from Carbolite Gero’s tube furnace range should be selected.
An extensive range of chamber / muffle furnaces is available for your laboratory.
Whether you need a small bench mounted affordable solution or a high temperature furnace built to the highest quality, Carbolite Gero has a model that is sure to meet your needs and budget. Ranging from the entry level ELF models at 1100°C through to the laboratory sized HTF model with a maximum temperature of 1800°C our experience of building quality furnaces for customers around the globe over the last eight decades has ensured that the Carbolite Gero name is synonymous with Leading Heat Technology.
Whether you need a front, top or bottom loading chamber furnace our extensive portfolio virtually guarantees there is an appropriate standard solution that will meet your requirements but of course our bespoke design service allows us to meet almost every scenario we have ever been consulted about.
Key Features
- High-Temperature Capability: The furnace can reach temperatures up to 1800°C, accommodating a wide range of laboratory heat treatment processes.
- Advanced Temperature Control: Equipped with sophisticated temperature controllers, it ensures accurate and consistent thermal management for precise experimental conditions.
- Robust Construction: Built with durable materials, the furnace offers longevity and reliability, making it suitable for demanding laboratory environments.
Available Models
Technical Specifications
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Max. continuous operating temp. [°C] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External H x W x D [mm] | Temperature uniformity of ±5°C within H x W x D [mm] | Volume [litres] | Max. power [W] | Holding power [W] | Thermocouple type | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|---|---|
ELF 11/6 | 1100 | 28 | 1000 | 165 x 180 x 210 | 580 x 410 x 420 | 125 x 140 x 140 | 6 | 2000 | 900 | K | 24 |
ELF 11/14 | 1100 | 43 | 1000 | 210 x 220 x 310 | 630 x 450 x 520 | 170 x 180 x 205 | 14 | 2600 | 1300 | K | 31 |
ELF 11/23 | 1100 | 26 | 1000 | 235 x 255 x 400 | 715 x 505 x 690 | 195 x 215 x 305 | 23 | 5000 | 1550 | K | 52 |
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Max. continuous operating temp. [°C] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External H x W x D [mm] | Dimensions: External with door open H x W x D [mm] | Temperature uniformity of ±5°C within H x W x D [mm] | Volume [litres] | Max. power [W] | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|---|
Standard Chamber Furnaces | ||||||||||
CWF 11/5 | 1100 | 47 | 1000 | 135 x 140 x 250 | 585 x 375 x 485 | 800 x 375 x 485 | 85 x 90 x 110 | 5 | 2400 | 30 |
CWF 11/13 | 1100 | 90 | 1000 | 200 x 200 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | 120 x 120 x 185 | 13 | 3100 | 47 |
CWF 11/23 | 1100 | 36 | 1000 | 235 x 245 x 400 | 705 x 505 x 675 | 990 x 505 x 675 | 155 x 165 x 285 | 23 | 7000 | 68 |
CWF 12/5 | 1200 | 51 | 1100 | 135 x 140 x 250 | 585 x 375 x 485 | 800 x 375 x 485 | 85 x 90 x 125 | 5 | 2400 | 30 |
CWF 12/13 | 1200 | 80 | 1100 | 200 x 200 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | 120 x 120 x 200 | 13 | 3100 | 47 |
CWF 12/23 | 1200 | 45 | 1100 | 235 x 245 x 400 | 705 x 505 x 675 | 990 x 505 x 675 | 155 x 165 x 325 | 23 | 7000 | 68 |
CWF 12/65 | 1200 | 40 | 1100 | 278 x 388 x 595 | 885 x 780 x 945 | 1245 x 780 x 945 | 178 x 288 x 455 | 65 | 14000 | 165 |
CWF 13/5 | 1300 | 75 | 1200 | 135 x 140 x 250 | 585 x 375 x 485 | 800 x 375 x 485 | 85 x 90 x 150 | 5 | 2400 | 30 |
CWF 13/13 | 1300 | 115 | 1200 | 200 x 200 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | 120 x 120 x 225 | 13 | 3100 | 47 |
CWF 13/23 | 1300 | 55 | 1200 | 235 x 245 x 400 | 705 x 505 x 675 | 990 x 505 x 675 | 155 x 165 x 340 | 23 | 7000 | 68 |
CWF 13/36 | 1300 | 47 | 1200 | 250 x 320 x 450 | 810 x 690 x 780 | 1105 x 690 x 780 | 1105 x 690 x 780 | 36 | 9000 | 100 |
CWF 13/65 | 1300 | 45 | 1200 | 278 x 388 x 595 | 885 x 780 x 945 | 1245 x 780 x 945 | 178 x 288 x 520 | 65 | 14000 | 165 |
Burn-off Chamber Furnaces | ||||||||||
CWF-B 11/13 | 1100 | 103 | 1000 | 200 x 200 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | n/a | 13 | 3100 | 47 |
CWF-B 12/13 | 1200 | 130 | 1100 | 200 x 200 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | n/a | 13 | 3100 | 47 |
Chamber Furnace with Integral Balance | ||||||||||
CWF-BAL 11/21 | 1100 | 60 | 1000 | 215 x 245 x 400 | 705 x 505 x 675 (400 x 170 x 500) | 990 x 505 x 675 | n/a | 21 | 7000 | 80 |
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Max. continuous operating temp. [°C] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External H x W x D [mm] | Temperature uniformity of ±5°C within H x W x D [mm] | Volume [litres] | Max. power [W] | Holding power [W] | Thermocouple type | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|---|---|
RWF 11/5 | 1100 | 10 | 1000 | 130 x 160 x 250 | 585 x 375 x 325 | 800 x 375 x 325 | 5 | 2750 | 680 | K | 28 |
RWF 11/13 | 1100 | 11 | 1000 | 195 x 210 x 325 | 655 x 435 x 610 | 905 x 435 x 610 | 13 | 5000 | 1200 | K | 45 |
RWF 11/23 | 1100 | 13 | 1000 | 220 x 260 x 400 | 705 x 505 x 675 | 990 x 505 x 675 | 23 | 9100 | 1800 | K | 65 |
RWF 12/5 | 1200 | 12 | 1100 | 130 x 160 x 250 | 585 x 375 x 485 | 800 x 375 x 485 | 5 | 2750 | 820 | R | 28 |
RWF 12/13 | 1200 | 13 | 1100 | 195 x 210 x 325 | 655 x 435 x 610 | 655 x 435 x 610 | 13 | 5000 | 1450 | R | 45 |
RWF 12/23 | 1200 | 15 | 1100 | 220 x 260 x 400 | 705 x 505 x 675 | 990 x 505 x 675 | 23 | 9100 | 2100 | R | 65 |
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Max. continuous operating temp. [°C] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External H x W x D [mm] | Temperature uniformity of ±5°C within H x W x D [mm] | Volume [litres] | Max. power [W] | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|
VCF 12/5 | 1200 | 102 | 260 x 155 x 130 | 660 x 530 x 405 (Floor-standing) | 5 | 2500 | 900 | R | 50 |
VCF 12/10 | 1200 | 138 | 365 x 180 x 155 | 765 x 555 x 430 (Floor-standing) | 10 | 3000 | 1200 | R | 60 |
VCF 12/23 | 1200 | 125 | 450 x 250 x 200 | 850 x 600 x 500 (Floor-standing) | 23 | 6000 | 2500 | R | 130 |
VCF 12/100 | 1200 | 150 | 600 x 410 x 410 | 1100 x 930 x 950 (Floor-standing) | 100 | 15000 | 6000 | R | 200 |
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External with door open H x W x D [mm] | Volume [litres] | Holding power [W] | Max. power [W] | Thermocouple type | Weight [kg] |
---|---|---|---|---|---|---|---|---|---|
RHF 14/3 | 1400 | 33 | 120 x 120 x 205 | 655 x 435 x 610 (905) (Bench-top) | 3 | 1900 | 4500 | R | 42 |
RHF 14/8 | 1400 | 22 | 170 x 170 x 270 | 705 x 505 x 675 (990) (Bench-top) | 8 | 3200 | 8000 | R | 64 |
RHF 14/15 | 1400 | 35 | 220 x 220 x 310 | 810 x 690 x780 (1105) (Bench-top) | 15 | 2900 | 10000 | R | 125 |
RHF 14/35 | 1400 | 38 | 250 x 300 x 465 | 885 x 780 x 945 (1245) (Benchtop) | 35 | 6000 | 16000 | R | 179 |
RHF 15/3 | 1500 | 45 | 120 x 120 x 205 | 655 x 435 x 610 (905) (Bench-top) | 3 | 2000 | 4500 | R | 46 |
RHF 15/8 | 1500 | 40 | 170 x 170 x 270 | 705 x 505 x 675 (990) (Bench-top) | 8 | 3500 | 8000 | R | 61 |
RHF 15/15 | 1500 | 46 | 220 x 220 x 310 | 810 x 690 x 780 (1105) (Bench-top) | 15 | 3000 | 10000 | R | 125 |
RHF 15/35 | 1500 | 46 | 250 x 300 x 465 | 885 x 780 x 945 (1245) (Bench-top) | 35 | 6200 | 16000 | R | 178 |
RHF 16/3 | 1600 | 42 | 120 x 120 x 205 | 655 x 435 x 610 (905) (Bench-top) | 3 | 2300 | 4500 | R | 42 |
RHF 16/8 | 1600 | 35 | 170 x 170 x 270 | 705 x 505 x 675 (990) (Bench-top) | 8 | 4000 | 8000 | R | 61 |
RHF 16/15 | 1600 | 58 | 220 x 220 x 310 | 810 x 690 x 780 (1105) (Bench-top) | 15 | 3500 | 10000 | R | 140 |
RHF 16/35 | 1600 | 113 | 250 x 300 x 465 | 1530 x 900 x 1020 (1885) (Floor-standing) | 35 | 7000 | 16000 | R | 270 |
CGH Model | Max. temp. [°C] | Heat-up time [mins] | Dimensions: Usable chamber H x W x D [mm] | Dimensions: External with door open H x W x D [mm] | Volume [litres] | Max. power [W] | Thermocouple type | Weight [kg] |
---|---|---|---|---|---|---|---|---|
HTF 17/5 | 1700 | 50 | 158 x 150 x 225 | 565 x 830 x 650 (850) (Bench-top) | 5 | 4050 | B | 109 |
HTF 17/10 | 1700 | 44 | 232 x 200 x 225 | 565 x 830 x 650 (850) (Bench-top) | 10 | 5920 | B | 133 |
HTF 18/4 | 1800 | 65 | 140 x 140 x 190 | 565 x 830 x 650 (850) (Bench-top) | 4 | 4650 | Pt20%Rh / Pt40%Rh | 115 |
HTF 18/8 | 1800 | 56 | 210 x 190 x 190 | 565 x 830 x 650 (850) (Bench-top) | 8 | 6200 | Pt20%Rh / Pt40%Rh | 128 |
Carbolite Gero – Leading Heat Technology – Ovens and Furnaces Up to 3,000 °C
More Products
The Carbolite Gero brand is synonymous with high quality, leading heat technology in the design and manufacture of laboratory and…