  • Spectra Analysis – Solid-phase deposition FTIR – DISCOVIR-GC™

    Boost Efficiency of Your Current Compound ID

    The new Spectra Analysis DiscovIR System is the perfect solution when identifying the components in a complex mixture. Infrared spectrosco...

    Boost Efficiency of Your Current Compound ID

    The new Spectra Analysis DiscovIR System is the perfect solution when identifying the components in a complex mixture. Infrared spectroscopy provides each compound’s unique fingerprint, making it quick and easy to identify each peak by comparison to the extensive solid phase IR libraries. The DiscovIR system is particularly useful in identifying structural isomers, which can be a challenging area for Mass Spectrometry.

    Micro-deposition Improves Analysis

    DiscovIR’s unique temperature controlled, vacuum deposition method ensures that results are accurate and reproducible. Eluted peaks are first deposited in a film onto a rotating IR-transparent disc. The disk rotates the concentrated spot into the infrared beam and the spectrum is collected.

    Drug exhibits have become more challenging over the years due to an increase in complex synthetic substances with many positional isomer and diastereomer possibilities. With the DiscovIR-GC® from Spectra Analysis Instruments, forensic and law enforcement labs can now easily and rapidly identify designer drugs, by-products, and cutting agents with a higher level of specificity and discrimination which is unattainable through mass spectrometry alone.

    Key Applications

    • Controlled substances
    • Amphetamines
    • Diastereomers
    • Ephedrine/pseudoephedrine
    • Trace analysis
    • Fentanyl analogs
    • Cathinones
    • Phenethylamines
  • Spectra Analysis – Solid-phase deposition FTIR – DISCOVIR-LC™

    Micro-deposition Improves Analysis

    DiscovIR’s unique temperature controlled, vacuum deposition method ensures that results are accurate and reproducible. Eluted peaks are first depo...

    Micro-deposition Improves Analysis

    DiscovIR’s unique temperature controlled, vacuum deposition method ensures that results are accurate and reproducible. Eluted peaks are first deposited in a film on to a rotating IR transparent disc. Next, an infrared beam passes through each concentrated spot and the detector automatically collects spectral data.

    Concentrates Analytes In Minimal Area

    Cryogenic temperature control of the Sample Disc minimizes the area of the deposited analyte. This results in a thicker sample layer and therefore Higher Sensitivity of the absorbance spectrum.

    New DiscovIR-LCTM system from Spectra Analysis is able to afford total solvent removal from a reversed-phase gradient run (2% to 100% organic) with no change in the operational setpoints of the system. Solid phase Transmission FTIR Spectra are acquired continuously throughout the run.

     

    Key Applications

    • Deformulation
    • Co-polymer compositional drift
    • Extractables and leachables
    • Minor component identification
    • Chemical troubleshooting
    • Degradation/failure analysis